Million Standard Cubic Feet per Day (MMSCFD)
MMSCFD是气体流量的单位表示standard temperature and pressure conditions. Volumetric flow of a gas depends strongly on the temperature and pressure conditions. Hence thestandard temperature and pressure conditionsprovide a very convenient reference point with commonly known temperature and pressure value. Volumetric gas flow expressed at standard conditions can be readily converted to mass or molar flow of that gas which is independent of pressure or temperature values.
Following sample problem demonstrates how MMSCFD value can be calculated based on its volumetric flow and pressure, temperature values at which this flow rate is expressed.
Sample Problem for MMSCFD calculation
What is the MMSCFD (Million Standard Cubic Feet per Day) flowrate corresponding to 100m3/hr of nitrogen flowing through a pipe? Operating temperature of nitrogen stream is 800C. Operating pressure at the point of flow measurement is 25 bar.
Standard conditionsdefined byNISTto be used.
Solution
The calculation of MMSCFD, first requires thestandard temperature and pressure conditionsto be fixed. Standard temperature and pressure conditions defined by NIST are to be used, as specified in the problem statement.
Standard Temperature TS= 00C= 273.16 K
Standard Pressure PS= 101.325 kPa
The operating conditions are,
Volumetric gas flow V = 100m3/hr
Gas temperature T = 800C= 353.16 K
Gas pressure P = 25 bar = 2500 kPa
Gas volume is directly proportional to temperature and inversely proportional to pressure.
Gas flow at standard conditions is calculated as,
VStandard= V×(TS/T)×(P/ PS)
= 100×(273.16/353.16)×(2500/101.325) m3/hr
= 1908.4 SM3/hr
= 1908.4×(3.28)3/(1/24) ft3/day
= 1616226.3 ft3/day
Gas flow = 1616226.3/106MMSCFD = 1.6162 MMSCFD
Alternatively, you can also use this 'MMSCFD conversion calculator' to quickly convert a gas flowrate to MMSCFD unit.